Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37138103

RESUMO

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Sistema de Registros , Desenho de Prótese
3.
EuroIntervention ; 19(6): 502-511, 2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37203860

RESUMO

BACKGROUND: Prospective data about transcatheter aortic valve implantation (TAVI) in bicuspid aortic valve (BAV) patients are limited. AIMS: We aimed to evaluate the clinical impact of the Evolut PRO and R (34 mm) self-expanding prostheses in BAV patients and explore the impact of different computed tomography (CT) sizing algorithms in a prospective registry. METHODS: A total of 149 bicuspid patients were treated in 14 countries. The primary endpoint was the intended valve performance at 30 days. Secondary endpoints were 30-day and 1-year mortality, severe patient-prosthesis mismatch (PPM) and the ellipticity index at 30 days. All study endpoints were adjudicated according to Valve Academic Research Consortium 3 criteria. RESULTS: The mean Society of Thoracic Surgeons score was 2.6% (1.7-4.2). Type I L-R BAV was observed in 72.5% of the patients. Evolut valve sizes 29 and 34 mm were utilised in 49.0% and 36.9% of the cases, respectively. The 30-day cardiac death rate was 2.6%; the 1-year cardiac death rate was 11.0%. Valve performance at 30 days was observed in 142/149 (95.3%) patients. The mean aortic valve area post-TAVI was 2.1 (1.8-2.6) cm2, and the mean aortic gradient was 7.2 (5.4-9.5) mmHg. No patient had more than moderate aortic regurgitation at 30 days. PPM was observed in 13/143 (9.1%) surviving patients and was severe in 2 patients (1.6%). Valve function was maintained at 1 year. The mean ellipticity index remained 1.3 (interquartile range 1.2-1.4). Overall, 30-day and 1-year clinical and echocardiography outcomes were similar between the two sizing strategies. CONCLUSIONS: BIVOLUTX demonstrated a favourable bioprosthetic valve performance and good clinical outcomes after TAVI with the Evolut platform in patients with bicuspid aortic stenosis. No impact from the sizing methodology could be identified.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Estenose da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Doença da Válvula Aórtica Bicúspide/etiologia , Doença da Válvula Aórtica Bicúspide/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Constrição Patológica , Resultado do Tratamento , Desenho de Prótese , Estudos Prospectivos , Doenças das Valvas Cardíacas/cirurgia , Estenose da Valva Mitral/cirurgia , Sistema de Registros , Morte
4.
Int J Cardiol ; 378: 159-163, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36828032

RESUMO

BACKGROUND: Left ventricular (LV) remodeling in severe aortic valve stenosis (AS) is a complex process that goes beyond hypertrophic response. Reparative/replacement fibrosis is considered irreversible and has recognized value in both risk stratification and prognosis. Currently, cardiac magnetic resonance (CMR) is the gold-standard imaging technique for fibrosis identification through late gadolinium enhancement (LGE) assessment. However, its prevalence and distribution are quite variable among series. Our goal was to assess LGE prevalence and patterns in severe AS. METHODOLOGY: Single-center prospective cohort of 140 patients with severe symptomatic high-gradient AS (mean age 72 ± 8 years; mean valvular transaortic gradient 61 ± 18 mmHg; mean LV ejection fraction by echocardiogram 58 ± 9%) undergoing surgical aortic valve replacement. Those with previous myocardial infarction and/or non-ischemic cardiomyopathy were excluded. All patients performed 1.5 T LGE-CMR prior to surgery. RESULTS: Overall, 103 patients (74%) had non-ischemic LGE (median LGE mass 2.8 g [IQR 0.0-7.8] g), many of them with combined mid-wall and junctional enhancement pattern (36%). LGE was most frequently observed in the mid-basal segments of the interventricular septum. Seventy-four patients (53%) had non-exclusively junctional LGE. Contrary to those with junctional enhancement, patients with non-exclusively junctional LGE had higher LV volumes/mass, worse LV ejection fraction and worse global longitudinal strain. CONCLUSION: Among patients with severe, symptomatic, high-gradient AS, LGE is frequent, primarily affecting the mid-basal interventricular septum. Contrary to junctional LGE, the presence of non-junctional LGE seems to correlate with adverse markers of LV remodeling.


Assuntos
Estenose da Valva Aórtica , Meios de Contraste , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos Prospectivos , Prevalência , Gadolínio , Função Ventricular Esquerda , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Fibrose , Valva Aórtica , Imagem Cinética por Ressonância Magnética/métodos , Valor Preditivo dos Testes
5.
Rev Port Cardiol ; 42(1): 39-40, 2023 01.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36460273
6.
Port J Card Thorac Vasc Surg ; 29(2): 23-29, 2022 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-35780419

RESUMO

AIMS: The aims of this study were to analyze early and late outcomes of TVS and identify predictors of short and long- term poor prognosis. METHODS: Single centre retrospective study with 130 patients who underwent TVS between 2007 and 2020. Most of the patients were female (72.3%), mean age of 64.4 years; 61.1% were in New York Heart Association class III/IV, with a EuroSCORE II of 7.5%. Univariable and Multivariable analyses were undertaken to identify predictors of perioperative mortality and morbidity and long-term mortality. RESULTS: In-hospital mortality was 10.8%, of which 7.6% were due to a cardiac cause. Diabetes Mellitus was an in- dependent predictor of increased perioperative mortality. This group had 27.7% rate of major perioperative complications. Elevated systolic pulmonary pressure and obesity were predictors of early morbidity. All-cause mortality was 43.1% for 14 years. The survival at 1, 5 and 10 years was 83%, 60% and 43%, respectively. Diabetes Mellitus was a risk factor for long-term mortality. CONCLUSIONS: Patients undergoing TVS have a high surgical risk making TVS an operation associated with high mor- tality and morbidity. This research suggests Diabetes Mellitus, pulmonary hypertension and obesity as risk factors for mortality in TVS.


Assuntos
Hipertensão Pulmonar , Feminino , Seguimentos , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Estudos Retrospectivos
7.
Panminerva Med ; 64(4): 427-437, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35638242

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established management strategy for severe aortic valve stenosis. Percutaneous axillary approach for TAVI holds the promise of improving safety without jeopardizing effectiveness in comparison to surgical access. We aimed at appraising the comparative effectiveness of percutaneous vs. surgical axillary approaches for TAVI. METHODS: We performed an international retrospective observational study using de-identified details on baseline, procedural, and 1-month follow-up features. Valve Academic Research Consortium (VARC)-3 criteria were applied throughout. Outcomes of interest were clinical events up to 1 month of follow-up, compared with unadjusted and propensity score-adjusted analyses. RESULTS: A total of 432 patients were included, 189 (43.8%) receiving surgical access, and 243 (56.2%) undergoing percutaneous access. Primary hemostasis failure was more common in the percutaneous group (13.2% vs. 4.2%, P<0.001), leading to more common use of covered stent implantation (13.2% vs. 3.7%, P<0.001). Irrespectively, percutaneous access was associated with shorter hospital stay (-2.6 days [95% confidence interval: -5.0; -0.1], P=0.038), a lower risk of major adverse events (a composite of death, myocardial infarction, stroke, type 3 bleeding, and major access-site related complication; odds ratio=0.44 [0.21; 0.95], P=0.036), major access-site non-vascular complications (odds ratio=0.21 [0.06; 0.77], P=0.018), and brachial plexus impairment (odds ratio=0.16 [0.03; 0.76], P=0.021), and shorter hospital stay (-2.6 days [-5.0; -0.1], P=0.038). CONCLUSIONS: Percutaneous axillary access provides similar or better results than surgical access in patients undergoing TAVI with absolute or relative contraindications to femoral access.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Sistema de Registros , Estudos Retrospectivos , Valva Aórtica/cirurgia , Fatores de Risco
8.
Catheter Cardiovasc Interv ; 98(7): E1033-E1043, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34506074

RESUMO

BACKGROUND: Recent studies suggest the use of transcatheter aortic valve implantation (TAVI) as an alternative to surgical aortic valve replacement (SAVR) in lower risk populations, but real-world data are scarce. METHODS: Single-center retrospective study of patients undergoing SAVR (between June 2009 and July 2016, n = 682 patients) or TAVI (between June 2009 and July 2017, n = 400 patients). Low surgical risk was defined as EuroSCORE II (ES II) < 4% for single noncoronary artery bypass graft procedure. TAVI patients were propensity score-matched in a 1:1 ratio with SAVR patients, paired by age, New York Heart Association class, diabetes mellitus, chronic obstructive pulmonary disease, atrial fibrillation, creatinine clearance, and left ventricular ejection fraction < 50%. RESULTS: A total of 158 patients (79 SAVR and 79 TAVI) were matched (mean age 79 ± 6 years, 79 men). TAVI patients had a higher incidence of permanent pacemaker implantation (0% vs. 19%, p < 0.001) and more than mild paravalvular leak (4% vs. 18%, p = 0.009), but comparable rates of stroke, major or life-threatening bleeding, emergent cardiac surgery, new-onset atrial fibrillation, and need for renal replacement therapy. Hospital length-of-stay and 30-day mortality were similar. At a median follow-up of 4.5 years (IQR 3.0-6.9), treatment strategy did not influence all-cause mortality (HR 1.19, 95% CI 0.77-1.83, log rank p = 0.43) nor rehospitalization (crude subdistribution HR 1.56, 95% CI 0.71-3.41, p = 0.26). ES II remained the only independent predictor of long-term all-cause mortality (adjusted HR 1.40, 95% CI 1.04-1.90, p = 0.029). CONCLUSION: In this low surgical risk severe aortic stenosis population, we observed similar rates of 30-day and long-term all-cause mortality, despite higher rates of permanent pacemaker implantation and more than mild paravalvular leak in TAVI patients. The results of this small study suggest that both procedures are safe and effective in the short-term, while the Heart Team remains essential to assess both options on the long-term.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Masculino , Pontuação de Propensão , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda
9.
J Invasive Cardiol ; 33(6): E431-E442, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33955846

RESUMO

AIM: To evaluate gender differences and mortality trends in a population undergoing transcatheter aortic valve implantation (TAVI) and to analyze the correlates to all-cause mortality at follow-up. METHODS: The study comprises a prospective cohort of 592 TAVI patients (53.4% female) treated between 2008 and 2018. Mortality differences between genders at different timepoints were assessed according to log rank test. Predictors of all-cause mortality at follow-up were identified using a univariate model and were then analyzed through multivariate Cox proportional hazard models. RESULTS: Compared with female patients, males were younger (81 ± 7.5 years vs 84.3 ± 5.3 years) and presented more comorbidities. Twelve female and 8 male patients (3.5%) died in the first 30 days after TAVI. Despite a higher Society of Thoracic Surgeons (STS) score in women, all-cause mortality rates at 30 days and 1 year were comparable. At long-term follow-up, female patients demonstrated better survival rates, despite a higher number of periprocedural complications. Correlates identified in men were the presence of diabetes and previous history of coronary artery bypass grafting, New York Heart Association class III/IV, pulmonary artery systolic pressure, and non-transfemoral access. None of these variables remained significant in the multivariable analysis. In females, only peripheral artery disease was associated with mortality. Shock and need for renal replacement were predictors of mortality in both genders, as was heart failure readmission after discharge. STS score was also shown to correlate with long-term mortality in both genders. CONCLUSION: Despite a higher STS score in women, 30-day mortality was not significantly different from men, while women present better clinical outcomes at long-term follow-up.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
Cardiovasc Revasc Med ; 28: 42-49, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32921596

RESUMO

AIM: To evaluate the real need for coronary access after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: Prospective observational single-center registry, including 563 consecutive patients who underwent TAVI between April 2008 and November 2018, with both self- and balloon-expandable valves in a tertiary European center. Mean age was 82.4 ±â€¯6.9 years, 53.3% were female, 16% had previous history of coronary artery bypass grafting, 33% of previous percutaneous coronary intervention (PCI), and 16.6% of myocardial infarction (MI). Twenty-four percent of the patients were revascularized within one year before TAVI in preparation for the procedure. Median Society of Thoracic Surgeons score was 4.82 (IQ 2.84). In a median follow-up of 24 months (IQ 21.5), 18 patients (3.2%) were identified as potentially in need for invasive coronary angiography: 9 (1.6%) in the setting of stable coronary artery disease and 9 (1.6%) for an acute coronary syndrome. A total of 11 PCIs were performed in 9 patients, with a complete success rate of 63.6%. Procedures that were unsuccessful or partially unsuccessful were due to the inability to cross the stent or the drug-eluting balloon through the valve struts or misplacement within the coronary artery due to lack of catheter support. CONCLUSION: In this population, a strategy of previous guideline-directed revascularization before TAVI was associated with a low rate of MI and repeated need of coronary access, with a scattered distribution over time. Assuring future access to coronary arteries in patients at increased risk may depend on the revascularization strategy rather than device selection.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Eur J Cardiothorac Surg ; 57(4): 799-800, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-31504380

RESUMO

A 74-year-old man was admitted with a post-acute myocardial infarction basal ventricular septal rupture. Onset of cardiogenic shock led to the implantation of a percutaneous veno-arterial extracorporeal membrane oxygenation (ECMO) system with an additional venous drainage cannula into the right ventricle. The ventricular septal defect was repaired with concomitant tricuspid valvuloplasty and mitral bioprosthesis implantation after 14 days. ECMO support was temporarily converted into a veno-venous system to wean the patient off cardiopulmonary bypass. The patient was discharged 3 weeks after surgery. This case illustrates the role of this extracorporeal life support system in the setting of postinfarction ventricular septal rupture.


Assuntos
Oxigenação por Membrana Extracorpórea , Comunicação Interventricular , Infarto do Miocárdio , Ruptura do Septo Ventricular , Idoso , Humanos , Masculino , Infarto do Miocárdio/complicações , Infarto do Miocárdio/cirurgia , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Ruptura do Septo Ventricular/diagnóstico por imagem , Ruptura do Septo Ventricular/etiologia , Ruptura do Septo Ventricular/cirurgia
12.
Arq. bras. cardiol ; 113(6): 1104-1111, Dec. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1055057

RESUMO

Abstract Background: Chronic kidney disease (CKD) is frequently present in patients with aortic valve disease. Decreased kidney perfusion as a consequence of reduced cardiac output may contribute to renal dysfunction in this setting. Objective: Given the potential reversibility of kidney hypoperfusion after valve repair, this study aimed to analyze the impact of percutaneous transcatheter aortic valve implantation (TAVI) on kidney function. Methods: We performed a retrospective analysis of 233 consecutive patients who underwent TAVI in a single center between November 2008 and May 2016. We assessed three groups according to their baseline estimated glomerular filtration rate (eGFR) (mL/min/1.73 m2): Group 1 with eGFR ≥ 60; Group 2 with 30 ≤ eGFR < 60; and Group 3 with eGFR < 30. We analyzed the eGFR one month and one year after TAVI in these three groups, using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) formula to calculate it. Results: Patients from Group 1 had a progressive decline in eGFR one year after the TAVI procedure (p < 0.001 vs. pre-TAVI). In Group 2 patients, the mean eGFR increased one month after TAVI and continued to grow after one year (p = 0.001 vs. pre-TAVI). The same occurred in Group 3, with the mean eGFR increasing from 24.4 ± 5.1 mL/min/1.73 m2 before TAVI to 38.4 ± 18.8 mL/min/1.73 m2 one year after TAVI (p = 0.012). Conclusions: For patients with moderate-to-severe CKD, kidney function improved one year after the TAVI procedure. This outcome is probably due to better kidney perfusion post-procedure. We believe that when evaluating patients that might need TAVI, this 'reversibility of CKD effect' should be considered.


Resumo Fundamento: Pacientes com doença valvar aórtica frequentemente apresentam doença renal crônica (DRC). Diminuição da perfusão renal como consequência da redução do débito cardíaco pode contribuir para a disfunção renal neste cenário. Objetivo: Dado o potencial de reversibilidade da hipoperfusão renal após o reparo valvar, este estudo teve o objetivo de analisar o impacto do implante percutâneo de válvula aórtica (TAVI - transcatheter aortic valve implantation) na função renal. Métodos: Foi realizada uma análise retrospectiva de 233 pacientes consecutivos submetidos ao TAVI em um único centro, entre novembro de 2008 e maio de 2016. Três grupos foram avaliados de acordo com a taxa de filtração glomerular estimada (TFGe) basal (mL/min/1,73 m2): Grupo 1 com TFGe ≥ 60; Grupo 2 com 30 ≤ TFGe < 60; e Grupo 3 com TFGe < 30. O TFGe foi analisado nestes três grupos um mês e um ano após o TAVI e calculado usando a fórmula do Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI). Resultados: Os pacientes do Grupo 1 tiveram um declínio progressivo da TFGe um ano após o procedimento TAVI (p < 0,001 vs. pré-TAVI). Nos pacientes do Grupo 2, a média da TFGe aumentou um mês depois do TAVI e continuou crescendo depois de um ano (p = 0,001 vs. pré-TAVI). O mesmo ocorreu no Grupo 3, com a média da TFGe subindo de 24,4 ± 5,1 mL/min/1,73 m2 antes do TAVI para 38,4 ± 18,8 mL/min/1,73 m2 um ano após o TAVI (p = 0,012). Conclusões: Em pacientes com DRC moderada a grave, a função renal melhorou um ano após o procedimento TAVI. Este resultado é provavelmente devido à melhora da perfusão renal pós-procedimento. Acredita-se que, ao avaliar pacientes que possam precisar de TAVI, este 'efeito de reversibilidade da DRC' deva ser considerado.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Insuficiência Renal Crônica/reabilitação , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/complicações , Comorbidade , Estudos Retrospectivos , Fatores de Risco , Insuficiência Renal Crônica/etiologia , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Taxa de Filtração Glomerular
13.
Arq Bras Cardiol ; 113(6): 1104-1111, 2019 12.
Artigo em Inglês, Português | MEDLINE | ID: mdl-31751440

RESUMO

BACKGROUND: Chronic kidney disease (CKD) is frequently present in patients with aortic valve disease. Decreased kidney perfusion as a consequence of reduced cardiac output may contribute to renal dysfunction in this setting. OBJECTIVE: Given the potential reversibility of kidney hypoperfusion after valve repair, this study aimed to analyze the impact of percutaneous transcatheter aortic valve implantation (TAVI) on kidney function. METHODS: We performed a retrospective analysis of 233 consecutive patients who underwent TAVI in a single center between November 2008 and May 2016. We assessed three groups according to their baseline estimated glomerular filtration rate (eGFR) (mL/min/1.73 m2): Group 1 with eGFR ≥ 60; Group 2 with 30 ≤ eGFR < 60; and Group 3 with eGFR < 30. We analyzed the eGFR one month and one year after TAVI in these three groups, using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) formula to calculate it. RESULTS: Patients from Group 1 had a progressive decline in eGFR one year after the TAVI procedure (p < 0.001 vs. pre-TAVI). In Group 2 patients, the mean eGFR increased one month after TAVI and continued to grow after one year (p = 0.001 vs. pre-TAVI). The same occurred in Group 3, with the mean eGFR increasing from 24.4 ± 5.1 mL/min/1.73 m2 before TAVI to 38.4 ± 18.8 mL/min/1.73 m2 one year after TAVI (p = 0.012). CONCLUSIONS: For patients with moderate-to-severe CKD, kidney function improved one year after the TAVI procedure. This outcome is probably due to better kidney perfusion post-procedure. We believe that when evaluating patients that might need TAVI, this 'reversibility of CKD effect' should be considered.


Assuntos
Estenose da Valva Aórtica/cirurgia , Insuficiência Renal Crônica/reabilitação , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Comorbidade , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/etiologia , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos
14.
Rev Port Cir Cardiotorac Vasc ; 26(2): 101-107, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31476809

RESUMO

OBJECTIVES: The goal of this study is to establish the relation between aortic bio prosthesis, patient prosthesis mismatch (PPM) and short-term mortality and morbidity as well as and long-term mortality. METHODS: This is a single center retrospective study with 812 patients that underwent isolated stented biologic aortic valve replacement between 2007 and 2016. The projected indexed orifice area was calculated using the in vivo previously published values. Outcomes were evaluated with the indexed effective orifice area (iEOA) as a continuous variable and/or nominal variable. Multivariable models were developed including clinically relevant co-variates. RESULTS: In the study population 65.9% (n=535) had no PPM, 32.6% (n=265) had moderate PPM and 1.5% (n=12) severe PPM. PPM was related with diabetes (OR:1.738, CI95:1.333-2.266; p<0.001), heart failure (OR:0.387, CI95:0.155-0.969; p=0.043) and older age (OR:1.494, CI95:1.171-1.907; p=0.001). iEOA was not an independent predictor of in-hospital mortality (OR 1.169, CI 0.039-35.441) or MACCE (OR 2.753, CI 0.287-26.453). Long term survival is significantly inferior with lower iEOA (HR 0.116, CI 0.041-0.332) and any degree of PPM decreases survival when compared with no PPM (Moderate: HR 1.542, CI 1.174-2.025; Severe HR 4.627, CI 2.083-10.276). CONCLUSIONS: PPM appears to have no impact on short-term outcomes including mortality and morbidity. At ten years follow-up, moderate or severe PPM significantly reduces the long-term survival.


Assuntos
Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas/efeitos adversos , Idoso , Bioprótese/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Desenho de Prótese , Falha de Prótese , Ajuste de Prótese , Estudos Retrospectivos , Resultado do Tratamento
16.
Am J Cardiol ; 123(5): 717-724, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30558758

RESUMO

Current recommendations on the optimal revascularization strategy in Non-ST-elevation myocardial infarction (NSTEMI) with left main (LM) or multivessel coronary disease (MVD) are based upon randomized clinical trials conducted in stable coronary artery disease. In a real-world contemporary observational registry, we compared the long-term outcome of NSTEMI patients with LM/MVD (n = 1,104) submitted to coronary artery bypass grafting (CABG), percutaneous coronary intervention (PCI), or optimized medical therapy (OMT). The primary end point was 5-year all-cause mortality. Results were assessed in the entire population (CABG 289, PCI 399, and OMT 416) and in a propensity score-matched cohort of CABG (n = 159) and PCI (n = 159). Crude 5-year mortality rates in CABG and PCI were 25.3% versus 29.6%, respectively (unadjusted hazard ratio [HR] 1.2; 95% confidence intervals [CI] 0.9 to 1.6; p = 0.212); OMT, however, was associated with a twofold higher risk of mortality when compared with any revascularization strategy (unadjusted HR 2.0; 95% CI 1.7 to 2.5; p < 0.001). After propensity score-matching and multivariate analysis, there was a trend toward a higher incidence of the primary end point in patients who underwent PCI versus CABG (31% vs 21%; adjusted HR 1.52; 95% CI 0.93 to 2.50; p = 0.094). This was a consistent finding over subgroups deemed clinically relevant, such as in patients with LM or proximal left anterior descending disease, SYNergy between percutaneous coronary intervention with TAXus ≥23 and left ventricle ejection fraction <40%. In conclusion, in a real-world cohort of NSTEMI patients with LM/MVD, those selected for OMT had a dire outcome. Although adjusted 5-year mortality was statistically similar between revascularization strategies, there was a trend favoring CABG, which might be the preferred option in LM, proximal LAD, SYNergy between percutaneous coronary intervention with TAXus ≥23, and left ventricle ejection fraction <40% subgroups.


Assuntos
Ponte de Artéria Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/cirurgia , Intervenção Coronária Percutânea/métodos , Pontuação de Propensão , Sistema de Registros , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Vasos Coronários/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Estudos Retrospectivos , Resultado do Tratamento
18.
Rev Port Cardiol (Engl Ed) ; 37(7): 585-590, 2018 Jul.
Artigo em Inglês, Português | MEDLINE | ID: mdl-30008314

RESUMO

INTRODUCTION: Surgical risk scores are widely used to identify patients at high surgical risk who may benefit from transcatheter aortic valve implantation (TAVI). A multiparametric TAVI mortality risk score based on a French registry (FRANCE-2) has recently been developed. The aim of our study was to compare the 30-day mortality prediction performance of the FRANCE-2, EuroSCORE II and STS scores. METHODS: We retrospectively studied 240 patients from a single-center prospective registry who underwent TAVI between January 2008 and December 2015. All scores were assessed for calibration and discrimination using calibration-in-the-large and ROC curve analysis, respectively. RESULTS: The observed mortality was 5.8% (n=14). The median EuroSCORE II, STS and FRANCE-2 scores were 5.0 (IQR 3.2-8.3), 5.1 (IQR 3.6-7.1) and 2.0 (IQR 1.0-3.0), respectively. Discriminative power was greater for EuroSCORE II (C-statistic 0.67) and STS (C-statistic 0.67) than for FRANCE-2 (C-statistic 0.53), but this was not statistically significant (p=0.26). All scores showed adequate calibration. CONCLUSIONS: All scores showed modest performance in early mortality prediction after TAVI. Despite being derived from a TAVI population, FRANCE-2 was no better than surgical risk scores in our population.


Assuntos
Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Prognóstico , Estudos Retrospectivos
19.
Rev Port Cardiol (Engl Ed) ; 37(1): 67-73, 2018 Jan.
Artigo em Inglês, Português | MEDLINE | ID: mdl-29317115

RESUMO

INTRODUCTION: Natriuretic peptides are ubiquitously used for diagnosis, follow-up and prognostic assessment in various heart conditions. N-terminal pro-brain natriuretic peptide (NT-proBNP) correlates with aortic stenosis severity, however its significance after transcatheter aortic valve implantation (TAVI) is not well established. AIM: We aimed to assess the prognostic value of NT-proBNP at one year in patients undergoing TAVI. METHODS: This single-center retrospective analysis included 151 patients in whom both baseline and one-month post-procedure NT-proBNP were measured, from 206 consecutive patients undergoing TAVI between November 2008 and December 2014. The best cut-off values of both baseline and one-month post-TAVI NT-proBNP for one-year mortality were determined by receiver operating characteristic curve analysis. Independent predictors of one-year mortality were assessed by Cox regression. RESULTS: The areas under the curve of baseline and post-procedural NT-proBNP for one-year mortality were 0.60 and 0.72, with the best cut-off values of 1350 and 2500 pg/ml, respectively. Atrial fibrillation, procedure-related major bleeding, baseline NT-proBNP higher than 1350 pg/ml, post-procedural NT-proBNP higher than 2500 pg/ml, higher creatinine and Society of Thoracic Surgeons score, and lower left ventricular ejection fraction were associated with one-year mortality. Only post-procedural NT-proBNP was independently and negatively associated with one-year survival (HR 5.9, 95% CI 1.6-21.7, p=0.008). CONCLUSIONS: Baseline NT-proBNP did not predict one-year mortality; on the other hand one-month post-procedural NT-proBNP higher than 2500 pg/ml may identify a high-risk subset of patients, allowing better management, care and hypothetically outcome.


Assuntos
Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Período Pós-Operatório , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...